| 概要 | A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands. |
|---|---|
| 公表日 | 2017年6月30日12:29 |
| 登録日 | 2021年1月26日13:29 |
| 最終更新日 | 2024年11月21日12:32 |
| CVSS3.0 : CRITICAL | |
| スコア | 9.8 |
|---|---|
| ベクター | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| 攻撃元区分(AV) | ネットワーク |
| 攻撃条件の複雑さ(AC) | 低 |
| 攻撃に必要な特権レベル(PR) | 不要 |
| 利用者の関与(UI) | 不要 |
| 影響の想定範囲(S) | 変更なし |
| 機密性への影響(C) | 高 |
| 完全性への影響(I) | 高 |
| 可用性への影響(A) | 高 |
| CVSS2.0 : MEDIUM | |
| スコア | 5.0 |
|---|---|
| ベクター | AV:N/AC:L/Au:N/C:P/I:N/A:N |
| 攻撃元区分(AV) | ネットワーク |
| 攻撃条件の複雑さ(AC) | 低 |
| 攻撃前の認証要否(Au) | 不要 |
| 機密性への影響(C) | 低 |
| 完全性への影響(I) | なし |
| 可用性への影響(A) | なし |
| 全ての特権を取得 | いいえ |
| ユーザー権限を取得 | いいえ |
| その他の権限を取得 | いいえ |
| ユーザー操作が必要 | いいえ |
| 構成1 | 以上 | 以下 | より上 | 未満 | |
| cpe:2.3:o:ge:multilin_sr_750_feeder_protection_relay_firmware:*:*:*:*:*:*:*:* | 5.02 | ||||
| 実行環境 | |||||
| 1 | cpe:2.3:h:ge:multilin_sr_750_feeder_protection_relay:-:*:*:*:*:*:*:* | ||||
| 構成2 | 以上 | 以下 | より上 | 未満 | |
| cpe:2.3:o:ge:multilin_sr_760_feeder_protection_relay_firmware:*:*:*:*:*:*:*:* | 5.02 | ||||
| 実行環境 | |||||
| 1 | cpe:2.3:h:ge:multilin_sr_760_feeder_protection_relay:-:*:*:*:*:*:*:* | ||||
| 構成3 | 以上 | 以下 | より上 | 未満 | |
| cpe:2.3:o:ge:multilin_sr_469_motor_protection_relay_firmware:*:*:*:*:*:*:*:* | 2.90 | ||||
| 実行環境 | |||||
| 1 | cpe:2.3:h:ge:multilin_sr_469_motor_protection_relay:-:*:*:*:*:*:*:* | ||||
| 構成4 | 以上 | 以下 | より上 | 未満 | |
| cpe:2.3:o:ge:multilin_sr_489_generator_protection_relay_firmware:*:*:*:*:*:*:*:* | 1.53 | ||||
| 実行環境 | |||||
| 1 | cpe:2.3:h:ge:multilin_sr_489_generator_protection_relay:-:*:*:*:*:*:*:* | ||||
| 構成5 | 以上 | 以下 | より上 | 未満 | |
| cpe:2.3:o:ge:multilin_sr_745_transformer_protection_relay_firmware:*:*:*:*:*:*:*:* | 2.85 | ||||
| 実行環境 | |||||
| 1 | cpe:2.3:h:ge:multilin_sr_745_transformer_protection_relay:-:*:*:*:*:*:*:* | ||||
| 構成6 | 以上 | 以下 | より上 | 未満 | |
| cpe:2.3:o:ge:multilin_sr_369_motor_protection_relay_firmware:-:*:*:*:*:*:*:* | |||||
| 実行環境 | |||||
| 1 | cpe:2.3:h:ge:multilin_sr_369_motor_protection_relay:-:*:*:*:*:*:*:* | ||||
| 構成7 | 以上 | 以下 | より上 | 未満 | |
| cpe:2.3:o:ge:multilin_universal_relay_firmware:*:*:*:*:*:*:*:* | 6.0 | ||||
| 実行環境 | |||||
| 1 | cpe:2.3:h:ge:multilin_universal_relay:-:*:*:*:*:*:*:* | ||||
| 構成8 | 以上 | 以下 | より上 | 未満 | |
| cpe:2.3:o:ge:multilin_urplus_d90_firmware:-:*:*:*:*:*:*:* | |||||
| 実行環境 | |||||
| 1 | cpe:2.3:h:ge:multilin_urplus_d90:-:*:*:*:*:*:*:* | ||||
| 構成9 | 以上 | 以下 | より上 | 未満 | |
| cpe:2.3:o:ge:multilin_urplus_c90_firmware:-:*:*:*:*:*:*:* | |||||
| 実行環境 | |||||
| 1 | cpe:2.3:h:ge:multilin_urplus_c90:-:*:*:*:*:*:*:* | ||||
| 構成10 | 以上 | 以下 | より上 | 未満 | |
| cpe:2.3:o:ge:multilin_urplus_b95_firmware:-:*:*:*:*:*:*:* | |||||
| 実行環境 | |||||
| 1 | cpe:2.3:h:ge:multilin_urplus_b95:-:*:*:*:*:*:*:* | ||||
| タイトル | 複数の General Electric 製品における暗号に関する脆弱性 |
|---|---|
| 概要 | 複数の General Electric (GE) 製品には、暗号に関する脆弱性が存在します。 |
| 想定される影響 | 情報を取得される、情報を改ざんされる、およびサービス運用妨害 (DoS) 状態にされる可能性があります。 |
| 対策 | ベンダ情報および参考情報を参照して適切な対策を実施してください。 |
| 公表日 | 2017年4月27日0:00 |
| 登録日 | 2017年8月3日16:52 |
| 最終更新日 | 2017年8月3日16:52 |
| General Electric Company |
| SR 369 Motor Protection Relay ファームウェア すべてのバージョン |
| SR 469 Motor Protection Relay ファームウェア 5.23 未満 |
| SR 489 Generator Protection Relay ファームウェア 4.06 未満 |
| SR 745 Transformer Protection Relay ファームウェア 5.23 未満 |
| SR 750 Feeder Protection Relay ファームウェア 7.47 未満 |
| SR 760 Feeder Protection Relay ファームウェア 7.47 未満 |
| Universal Relay ファームウェア 6.0 およびそれ以前 |
| URplus B95 すべてのバージョン |
| URplus C90 すべてのバージョン |
| URplus D90 すべてのバージョン |
| No | 変更内容 | 変更日 |
|---|---|---|
| 0 | [2017年08月03日] 掲載 |
2018年2月17日10:37 |