NVD Vulnerability Detail
Search Exploit, PoC
CVE-2026-25599
Summary

Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an
unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an
attacker to impersonate a legitimate device and inject malicious
payloads. This enables the insertion of harmful code directly
into the Orca user portal, potentially compromising user accounts,
exposing sensitive information, and allowing further unauthorized
actions within the portal.

Publication Date June 1, 2026, 8:16 p.m.
Registration Date June 2, 2026, 4:17 a.m.
Last Update June 2, 2026, 3:02 a.m.
CVSS3.1 : MEDIUM
スコア 6.3
Vector CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L
攻撃元区分(AV) ネットワーク
攻撃条件の複雑さ(AC)
攻撃に必要な特権レベル(PR) 不要
利用者の関与(UI)
影響の想定範囲(S) 変更なし
機密性への影響(C)
完全性への影響(I)
可用性への影響(A)
Related information, measures and tools
Common Vulnerabilities List