267291
|
8.0 |
HIGH
Network
|
ewon
|
ewon_firmware
|
Cross-site request forgery (CSRF) vulnerability on eWON devices with firmware through 10.1s0 allows remote attackers to hijack the authentication of administrators for requests that trigger firmware …
|
CWE-352
Origin Validation Error
|
CVE-2015-7925
|
2024-11-21 11:37 |
2015-12-23 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
267292
|
8.8 |
HIGH
Network
|
ewon
|
ewon_firmware
|
eWON devices with firmware before 10.1s0 do not trigger the discarding of browser session data in response to a log-off action, which makes it easier for remote attackers to obtain access by leveragi…
|
NVD-CWE-Other
|
CVE-2015-7924
|
2024-11-21 11:37 |
2015-12-23 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
267293
|
7.5 |
HIGH
Network
|
motorola
|
moscad_ip_gateway_firmware
|
Cross-site request forgery (CSRF) vulnerability in Motorola Solutions MOSCAD IP Gateway allows remote attackers to hijack the authentication of administrators for requests that modify a password.
|
CWE-352
Origin Validation Error
|
CVE-2015-7936
|
2024-11-21 11:37 |
2015-12-23 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
267294
|
7.5 |
HIGH
Network
|
motorola
|
moscad_ip_gateway_firmware
|
Motorola Solutions MOSCAD IP Gateway allows remote attackers to read arbitrary files via unspecified vectors.
|
CWE-200
Information Exposure
|
CVE-2015-7935
|
2024-11-21 11:37 |
2015-12-23 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
267295
|
7.2 |
HIGH
Local
|
opcsystems
|
opc_systems.net
|
Untrusted search path vulnerability in Open Automation OPC Systems.NET 8.00.0023 and earlier allows local users to gain privileges via a Trojan horse DLL in an unspecified directory.
|
NVD-CWE-Other
|
CVE-2015-7917
|
2024-11-21 11:37 |
2015-12-23 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
267296
|
9.1 |
CRITICAL
Network
|
saia_burgess_controls
|
pcd7.d4xxv_vga_mb_firmware pcd7.d4xxd_firmware pcd3.mxxx0_firmware pcd7.d4xxd_svga_mb_firmware pcd3.t666_firmware pcd1.m2xx0_firmware pcd3.mxx60_firmware pcd3.t665_firmware pc…
|
Saia Burgess PCD1.M0xx0, PCD1.M2xx0, PCD2.M5xx0, PCD3.Mxx60, PCD3.Mxxx0, PCD7.D4xxD, PCD7.D4xxV, PCD7.D4xxWTPF, and PCD7.D4xxxT5F devices before 1.24.50 and PCD3.T665 and PCD3.T666 devices before 1.2…
|
CWE-255
Credentials Management
|
CVE-2015-7911
|
2024-11-21 11:37 |
2015-12-23 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
267297
|
- |
|
schneider-electric
|
bmxnoe0110h bmxpra0100 bmxnoc0401 bmxnor0200h bmxnoe0100 bmxnor0200 bmxnoe0110 bmxnoe0100h modicon_m340_bmxp342020 modicon_m340_bmxp342030 modicon_m340_bmxp3420302 mo…
|
Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Bas…
|
CWE-119
Incorrect Access of Indexable Resource ('Range Error')
|
CVE-2015-7937
|
2024-11-21 11:37 |
2015-12-21 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
267298
|
10.0 |
CRITICAL
Network
|
searchblox
|
searchblox
|
SearchBlox 8.3 before 8.3.1 allows remote attackers to write to the config file, and consequently cause a denial of service (application crash), via unspecified vectors.
|
CWE-264
Permissions, Privileges, and Access Controls
|
CVE-2015-7919
|
2024-11-21 11:37 |
2015-12-21 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
267299
|
- |
|
honeywell
|
midas_firmware midas_black_firmware
|
Honeywell Midas gas detectors before 1.13b3 and Midas Black gas detectors before 2.13b3 allow remote attackers to discover cleartext passwords by sniffing the network.
|
CWE-200
Information Exposure
|
CVE-2015-7908
|
2024-11-21 11:37 |
2015-12-21 |
Show
|
GitHub
Exploit DB
Packet Storm
|
|
|
|
267300
|
8.6 |
HIGH
Network
|
honeywell
|
midas_black_firmware midas_firmware
|
Directory traversal vulnerability in the web server on Honeywell Midas gas detectors before 1.13b3 and Midas Black gas detectors before 2.13b3 allows remote attackers to bypass authentication, and wr…
|
CWE-22
Path Traversal
|
CVE-2015-7907
|
2024-11-21 11:37 |
2015-12-21 |
Show
|
GitHub
Exploit DB