| Summary | A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected devices does not properly handle the error in case of exceeding characters while setting SNMP leading to the restart of the application. |
|---|---|
| Publication Date | Sept. 10, 2024, 7:15 p.m. |
| Registration Date | Sept. 11, 2024, 5:01 a.m. |
| Last Update | Sept. 19, 2024, 12:31 a.m. |
| CVSS3.1 : HIGH | |
| スコア | 7.5 |
|---|---|
| Vector | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| 攻撃元区分(AV) | ネットワーク |
| 攻撃条件の複雑さ(AC) | 低 |
| 攻撃に必要な特権レベル(PR) | 不要 |
| 利用者の関与(UI) | 不要 |
| 影響の想定範囲(S) | 変更なし |
| 機密性への影響(C) | なし |
| 完全性への影響(I) | なし |
| 可用性への影響(A) | 高 |
| Configuration1 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_rf360r_firmware:*:*:*:*:*:*:*:* | 2.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_rf360r:-:*:*:*:*:*:*:* | ||||
| Configuration2 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_rf1170r_firmware:*:*:*:*:*:*:*:* | 1.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_rf1170r:-:*:*:*:*:*:*:* | ||||
| Configuration3 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_rf1140r_firmware:*:*:*:*:*:*:*:* | 1.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_rf1140r:-:*:*:*:*:*:*:* | ||||
| Configuration4 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf685r_fcc_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf685r_fcc:-:*:*:*:*:*:*:* | ||||
| Configuration5 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf685r_etsi_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf685r_etsi:-:*:*:*:*:*:*:* | ||||
| Configuration6 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf685r_cmiit_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf685r_cmiit:-:*:*:*:*:*:*:* | ||||
| Configuration7 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf685r_arib_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf685r_arib:-:*:*:*:*:*:*:* | ||||
| Configuration8 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf680r_fcc_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf680r_fcc:-:*:*:*:*:*:*:* | ||||
| Configuration9 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf680r_etsi_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf680r_etsi:-:*:*:*:*:*:*:* | ||||
| Configuration10 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf680r_cmiit_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf680r_cmiit:-:*:*:*:*:*:*:* | ||||
| Configuration11 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf680r_arib_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf680r_arib:-:*:*:*:*:*:*:* | ||||
| Configuration12 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf650r_fcc_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf650r_fcc:-:*:*:*:*:*:*:* | ||||
| Configuration13 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf650r_etsi_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf650r_etsi:-:*:*:*:*:*:*:* | ||||
| Configuration14 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf650r_cmiit_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf650r_cmiit:-:*:*:*:*:*:*:* | ||||
| Configuration15 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf650r_arib_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf650r_arib:-:*:*:*:*:*:*:* | ||||
| Configuration16 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf615r_fcc_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf615r_fcc:-:*:*:*:*:*:*:* | ||||
| Configuration17 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf615r_etsi_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf615r_etsi:-:*:*:*:*:*:*:* | ||||
| Configuration18 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf615r_cmiit_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf615r_cmiit:-:*:*:*:*:*:*:* | ||||
| Configuration19 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf610r_fcc_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf610r_fcc:-:*:*:*:*:*:*:* | ||||
| Configuration20 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf610r_etsi_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf610r_etsi:-:*:*:*:*:*:*:* | ||||
| Configuration21 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_reader_rf610r_cmiit_firmware:*:*:*:*:*:*:*:* | 4.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_reader_rf610r_cmiit:-:*:*:*:*:*:*:* | ||||
| Configuration22 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_rf188ci_firmware:*:*:*:*:*:*:*:* | 2.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_rf188ci:-:*:*:*:*:*:*:* | ||||
| Configuration23 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:* | 2.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:* | ||||
| Configuration24 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_rf186ci_firmware:*:*:*:*:*:*:*:* | 2.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_rf186ci:-:*:*:*:*:*:*:* | ||||
| Configuration25 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:* | 2.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:* | ||||
| Configuration26 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:* | 2.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:* | ||||
| Configuration27 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_rf166c_firmware:*:*:*:*:*:*:*:* | 2.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_rf166c:-:*:*:*:*:*:*:* | ||||
| Title | 複数のシーメンス製品における脆弱性 |
|---|---|
| Summary | SIMATIC RF360R ファームウェア、simatic rf1170r ファームウェア、simatic rf1140r ファームウェア等複数のシーメンス製品には、不特定の脆弱性が存在します。 |
| Possible impacts | サービス運用妨害 (DoS) 状態にされる可能性があります。 |
| Solution | ベンダアドバイザリまたはパッチ情報が公開されています。参考情報を参照して適切な対策を実施してください。 |
| Publication Date | Sept. 10, 2024, midnight |
| Registration Date | Sept. 19, 2024, 4:54 p.m. |
| Last Update | Sept. 19, 2024, 4:54 p.m. |
| シーメンス |
| simatic reader rf610r etsi ファームウェア 4.2 未満 |
| simatic reader rf610r fcc ファームウェア 4.2 未満 |
| simatic reader rf615r cmiit ファームウェア 4.2 未満 |
| simatic reader rf615r etsi ファームウェア 4.2 未満 |
| simatic reader rf615r fcc ファームウェア 4.2 未満 |
| simatic reader rf650r arib ファームウェア 4.2 未満 |
| simatic reader rf650r cmiit ファームウェア 4.2 未満 |
| simatic reader rf650r etsi ファームウェア 4.2 未満 |
| simatic reader rf650r fcc ファームウェア 4.2 未満 |
| simatic reader rf680r arib ファームウェア 4.2 未満 |
| simatic reader rf680r cmiit ファームウェア 4.2 未満 |
| simatic reader rf680r etsi ファームウェア 4.2 未満 |
| simatic reader rf680r fcc ファームウェア 4.2 未満 |
| simatic reader rf685r arib ファームウェア 4.2 未満 |
| simatic reader rf685r cmiit ファームウェア 4.2 未満 |
| simatic reader rf685r etsi ファームウェア 4.2 未満 |
| simatic reader rf685r fcc ファームウェア 4.2 未満 |
| simatic rf1140r ファームウェア 1.1 未満 |
| simatic rf1170r ファームウェア 1.1 未満 |
| SIMATIC RF360R ファームウェア 2.2 未満 |
| No | Changed Details | Date of change |
|---|---|---|
| 1 | [2024年09月19日] 掲載 |