CVE-2017-8413
| Summary |
An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The device runs a custom daemon on UDP port 5978 which is called "dldps2121" and listens for broadcast packets sent on 255.255.255.255. This daemon handles custom D-Link UDP based protocol that allows D-Link mobile applications and desktop applications to discover D-Link devices on the local network. The binary processes the received UDP packets sent from any device in "main" function. One path in the function traverses towards a block of code that handles commands to be executed on the device. The custom protocol created by D-Link follows the following pattern: Packetlen, Type of packet; M=MAC address of device or broadcast; D=Device Type;C=base64 encoded command string;test=1111. If a packet is received with the packet type being "S" or 0x53 then the string passed in the "C" parameter is base64 decoded and then executed by passing into a System API. We can see at address 0x00009B44 that the string received in packet type subtracts 0x31 or "1" from the packet type and is compared against 0x22 or "double quotes". If that is the case, then the packet is sent towards the block of code that executes a command. Then the value stored in "C" parameter is extracted at address 0x0000A1B0. Finally, the string received is base 64 decoded and passed on to the system API at address 0x0000A2A8 as shown below. The same form of communication can be initiated by any process including an attacker process on the mobile phone or the desktop and this allows a third-party application on the device to execute commands on the device without any authentication by sending just 1 UDP packet with custom base64 encoding.
|
| Publication Date |
July 3, 2019, 6:15 a.m. |
| Registration Date |
Jan. 26, 2021, 1:30 p.m. |
| Last Update |
Nov. 21, 2024, 12:33 p.m. |
|
CVSS3.1 : HIGH
|
| スコア |
8.8
|
| Vector |
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| 攻撃元区分(AV) |
隣接 |
| 攻撃条件の複雑さ(AC) |
低 |
| 攻撃に必要な特権レベル(PR) |
不要 |
| 利用者の関与(UI) |
不要 |
| 影響の想定範囲(S) |
変更なし |
| 機密性への影響(C) |
高 |
| 完全性への影響(I) |
高 |
| 可用性への影響(A) |
高 |
|
CVSS2.0 : HIGH
|
| Score |
8.3
|
| Vector |
AV:A/AC:L/Au:N/C:C/I:C/A:C |
| 攻撃元区分(AV) |
隣接 |
| 攻撃条件の複雑さ(AC) |
低 |
| 攻撃前の認証要否(Au) |
不要 |
| 機密性への影響(C) |
高 |
| 完全性への影響(I) |
高 |
| 可用性への影響(A) |
高 |
| Get all privileges. |
いいえ
|
| Get user privileges |
いいえ
|
| Get other privileges |
いいえ
|
| User operation required |
いいえ
|
Affected software configurations
| Configuration1 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dlink:dcs-1130_firmware:-:*:*:*:*:*:*:* |
|
|
|
|
| execution environment |
| 1 |
cpe:2.3:h:dlink:dcs-1130:-:*:*:*:*:*:*:* |
| Configuration2 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:dlink:dcs-1100_firmware:-:*:*:*:*:*:*:* |
|
|
|
|
| execution environment |
| 1 |
cpe:2.3:h:dlink:dcs-1100:-:*:*:*:*:*:*:* |
Related information, measures and tools
Common Vulnerabilities List
JVN Vulnerability Information
D-Link DCS-1100 および DCS-1130 デバイスにおけるコマンドインジェクションの脆弱性
| Title |
D-Link DCS-1100 および DCS-1130 デバイスにおけるコマンドインジェクションの脆弱性
|
| Summary |
D-Link DCS-1100 および DCS-1130 デバイスには、コマンドインジェクションの脆弱性が存在します。
|
| Possible impacts |
情報を取得される、情報を改ざんされる、およびサービス運用妨害 (DoS) 状態にされる可能性があります。 |
| Solution |
ベンダ情報および参考情報を参照して適切な対策を実施してください。 |
| Publication Date |
May 2, 2017, midnight |
| Registration Date |
July 11, 2019, 2:39 p.m. |
| Last Update |
July 11, 2019, 2:39 p.m. |
Affected System
| D-Link Systems, Inc. |
|
DCS-1100 ファームウェア
|
|
DCS-1130 ファームウェア
|
CVE (情報セキュリティ 共通脆弱性識別子)
CWE (共通脆弱性タイプ一覧)
ベンダー情報
その他
Change Log
| No |
Changed Details |
Date of change |
| 1 |
[2019年07月11日] 掲載 |
July 11, 2019, 2:39 p.m. |