NVD Vulnerability Detail
Search Exploit, PoC
CVE-2017-6754
Summary

A vulnerability in the web-based management interface of the Cisco Smart Net Total Care (SNTC) Software Collector Appliance 3.11 could allow an authenticated, remote attacker to perform a read-only, blind SQL injection attack, which could allow the attacker to compromise the confidentiality of the system through SQL timing attacks. The vulnerability is due to insufficient input validation of certain user-supplied fields that are subsequently used by the affected software to build SQL queries. An attacker could exploit this vulnerability by submitting crafted URLs, which are designed to exploit the vulnerability, to the affected software. To execute an attack successfully, the attacker would need to submit a number of requests to the affected software. A successful exploit could allow the attacker to determine the presence of values in the SQL database of the affected software. Cisco Bug IDs: CSCvf07617.

Publication Date Aug. 7, 2017, 3:29 p.m.
Registration Date Jan. 26, 2021, 1:27 p.m.
Last Update Nov. 21, 2024, 12:30 p.m.
CVSS3.0 : MEDIUM
スコア 6.5
Vector CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
攻撃元区分(AV) ネットワーク
攻撃条件の複雑さ(AC)
攻撃に必要な特権レベル(PR)
利用者の関与(UI) 不要
影響の想定範囲(S) 変更なし
機密性への影響(C)
完全性への影響(I) なし
可用性への影響(A) なし
CVSS2.0 : MEDIUM
Score 4.0
Vector AV:N/AC:L/Au:S/C:P/I:N/A:N
攻撃元区分(AV) ネットワーク
攻撃条件の複雑さ(AC)
攻撃前の認証要否(Au) 単一
機密性への影響(C)
完全性への影響(I) なし
可用性への影響(A) なし
Get all privileges. いいえ
Get user privileges いいえ
Get other privileges いいえ
User operation required いいえ
Affected software configurations
Configuration1 or higher or less more than less than
cpe:2.3:a:cisco:smart_net_total_care_collector_appliance:3.11:*:*:*:*:*:*:*
Related information, measures and tools
Common Vulnerabilities List

JVN Vulnerability Information
Cisco Smart Net Total Care Software Collector Appliance における SQL インジェクションの脆弱性
Title Cisco Smart Net Total Care Software Collector Appliance における SQL インジェクションの脆弱性
Summary

Cisco Smart Net Total Care (SNTC) Software Collector Appliance には、SQL インジェクションの脆弱性が存在します。 ベンダは、本脆弱性を Bug ID CSCvf07617 として公開しています。

Possible impacts 情報を取得される可能性があります。
Solution

ベンダ情報および参考情報を参照して適切な対策を実施してください。

Publication Date Aug. 2, 2017, midnight
Registration Date Sept. 5, 2017, 2:47 p.m.
Last Update Sept. 5, 2017, 2:47 p.m.
Affected System
シスコシステムズ
Cisco Smart Net Total Care Software Collector Appliance 3.11
CVE (情報セキュリティ 共通脆弱性識別子)
CWE (共通脆弱性タイプ一覧)
ベンダー情報
Change Log
No Changed Details Date of change
0 [2017年09月05日]
  掲載
Feb. 17, 2018, 10:37 a.m.