| Summary | Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. |
|---|---|
| Publication Date | May 11, 2017, 10:29 a.m. |
| Registration Date | Jan. 26, 2021, 1:22 p.m. |
| Last Update | Nov. 21, 2024, 12:23 p.m. |
| CVSS3.1 : MEDIUM | |
| スコア | 6.5 |
|---|---|
| Vector | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| 攻撃元区分(AV) | 隣接 |
| 攻撃条件の複雑さ(AC) | 低 |
| 攻撃に必要な特権レベル(PR) | 不要 |
| 利用者の関与(UI) | 不要 |
| 影響の想定範囲(S) | 変更なし |
| 機密性への影響(C) | なし |
| 完全性への影響(I) | なし |
| 可用性への影響(A) | 高 |
| CVSS2.0 : MEDIUM | |
| Score | 6.1 |
|---|---|
| Vector | AV:A/AC:L/Au:N/C:N/I:N/A:C |
| 攻撃元区分(AV) | 隣接 |
| 攻撃条件の複雑さ(AC) | 低 |
| 攻撃前の認証要否(Au) | 不要 |
| 機密性への影響(C) | なし |
| 完全性への影響(I) | なし |
| 可用性への影響(A) | 高 |
| Get all privileges. | いいえ |
| Get user privileges | いいえ |
| Get other privileges | いいえ |
| User operation required | いいえ |
| Configuration1 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_343-1_std_firmware:*:*:*:*:*:*:*:* | 3.1.3 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_343-1_std:-:*:*:*:*:*:*:* | ||||
| Configuration2 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_343-1_lean_firmware:*:*:*:*:*:*:*:* | 3.1.3 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_343-1_lean:-:*:*:*:*:*:*:* | ||||
| Configuration3 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_343-1_adv_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_343-1_adv:-:*:*:*:*:*:*:* | ||||
| Configuration4 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_443-1_std_firmware:*:*:*:*:*:*:*:* | 3.2.17 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_443-1_std:-:*:*:*:*:*:*:* | ||||
| Configuration5 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_443-1_adv_firmware:*:*:*:*:*:*:*:* | 3.2.17 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_443-1_adv:-:*:*:*:*:*:*:* | ||||
| Configuration6 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_443-1_opc-ua_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_443-1_opc-ua:-:*:*:*:*:*:*:* | ||||
| Configuration7 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_1243-1_firmware:*:*:*:*:*:*:*:* | 2.1.82 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_1243-1:-:*:*:*:*:*:*:* | ||||
| Configuration8 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cm_1542-1_firmware:*:*:*:*:*:*:*:* | 2.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cm_1542-1:-:*:*:*:*:*:*:* | ||||
| Configuration9 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_1542sp-1_firmware:*:*:*:*:*:*:*:* | 1.0.15 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_1542sp-1:-:*:*:*:*:*:*:* | ||||
| Configuration10 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_1542sp-1_irc_firmware:*:*:*:*:*:*:*:* | 1.0.15 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_1542sp-1_irc:-:*:*:*:*:*:*:* | ||||
| Configuration11 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_1543sp-1_firmware:*:*:*:*:*:*:*:* | 1.0.15 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_1543sp-1:-:*:*:*:*:*:*:* | ||||
| Configuration12 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_1543-1_firmware:*:*:*:*:*:*:*:* | 2.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_1543-1:-:*:*:*:*:*:*:* | ||||
| Configuration13 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_rf650r_firmware:*:*:*:*:*:*:*:* | 3.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_rf650r:-:*:*:*:*:*:*:* | ||||
| Configuration14 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_rf680r_firmware:*:*:*:*:*:*:*:* | 3.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_rf680r:-:*:*:*:*:*:*:* | ||||
| Configuration15 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_rf685r_firmware:*:*:*:*:*:*:*:* | 3.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_rf685r:-:*:*:*:*:*:*:* | ||||
| Configuration16 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_1616_firmware:*:*:*:*:*:*:*:* | 2.7 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_1616:-:*:*:*:*:*:*:* | ||||
| Configuration17 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_1604_firmware:*:*:*:*:*:*:*:* | 2.7 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_1604:-:*:*:*:*:*:*:* | ||||
| Configuration18 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_dk-1616_pn_io_firmware:*:*:*:*:*:*:*:* | 2.7 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_dk-1616_pn_io:-:*:*:*:*:*:*:* | ||||
| Configuration19 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:scalance_x200_firmware:*:*:*:*:*:*:*:* | 5.2.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:scalance_x200:-:*:*:*:*:*:*:* | ||||
| Configuration20 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:scalance_x200_irt_firmware:*:*:*:*:*:*:*:* | 5.4.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:scalance_x200_irt:-:*:*:*:*:*:*:* | ||||
| Configuration21 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:* | 4.1.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:* | ||||
| Configuration22 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:scalance_x408_firmware:*:*:*:*:*:*:*:* | 4.1.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:scalance_x408:-:*:*:*:*:*:*:* | ||||
| Configuration23 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:scalance_x414_firmware:*:*:*:*:*:*:*:* | 3.10.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:scalance_x414:-:*:*:*:*:*:*:* | ||||
| Configuration24 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:scalance_xm400_firmware:*:*:*:*:*:*:*:* | 6.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:scalance_xm400:-:*:*:*:*:*:*:* | ||||
| Configuration25 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:scalance_xr500_firmware:*:*:*:*:*:*:*:* | 6.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:scalance_xr500:-:*:*:*:*:*:*:* | ||||
| Configuration26 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:scalance_w700_firmware:*:*:*:*:*:*:*:* | 6.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:scalance_w700:-:*:*:*:*:*:*:* | ||||
| Configuration27 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:scalance_m-800_firmware:*:*:*:*:*:*:*:* | 4.03 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:scalance_m-800:-:*:*:*:*:*:*:* | ||||
| Configuration28 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:scalance_s615_firmware:*:*:*:*:*:*:*:* | 4.03 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:scalance_s615:-:*:*:*:*:*:*:* | ||||
| Configuration29 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:softnet_profinet_io_firmware:*:*:*:*:*:*:*:* | 14 | ||||
| cpe:2.3:o:siemens:softnet_profinet_io_firmware:14:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:softnet_profinet_io:-:*:*:*:*:*:*:* | ||||
| Configuration30 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:ie\/pb-link_firmware:*:*:*:*:*:*:*:* | 3.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:ie\/pb-link:-:*:*:*:*:*:*:* | ||||
| Configuration31 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:ie\/as-i_link_pn_io_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:ie\/as-i_link_pn_io:-:*:*:*:*:*:*:* | ||||
| Configuration32 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_standard_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_standard:-:*:*:*:*:*:*:* | ||||
| Configuration33 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_basic_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_basic:-:*:*:*:*:*:*:* | ||||
| Configuration34 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_teleservice_adapter_ie_advanced_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_teleservice_adapter_ie_advanced_modem:-:*:*:*:*:*:*:* | ||||
| Configuration35 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sitop_psu8600_firmware:*:*:*:*:*:*:*:* | 1.2.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sitop_psu8600:-:*:*:*:*:*:*:* | ||||
| Configuration36 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:ups1600_profinet_firmware:*:*:*:*:*:*:*:* | 2.2.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:ups1600_profinet:-:*:*:*:*:*:*:* | ||||
| Configuration37 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_et_200al_firmware:*:*:*:*:*:*:*:* | 1.0.2 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_et_200al:-:*:*:*:*:*:*:* | ||||
| Configuration38 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_et_200ecopn_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_et_200ecopn:-:*:*:*:*:*:*:* | ||||
| Configuration39 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_et_200m_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_et_200m:-:*:*:*:*:*:*:* | ||||
| Configuration40 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_et_200mp_firmware:*:*:*:*:*:*:*:* | 4.0.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_et_200mp:-:*:*:*:*:*:*:* | ||||
| Configuration41 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_et_200pro_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_et_200pro:-:*:*:*:*:*:*:* | ||||
| Configuration42 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_et_200s_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_et_200s:-:*:*:*:*:*:*:* | ||||
| Configuration43 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_et_200sp_firmware:*:*:*:*:*:*:*:* | 4.1.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_et_200sp:-:*:*:*:*:*:*:* | ||||
| Configuration44 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:pn\/pn_coupler_firmware:*:*:*:*:*:*:*:* | 4.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:pn\/pn_coupler:-:*:*:*:*:*:*:* | ||||
| Configuration45 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:*:*:*:*:*:*:*:* | 4.1.1 | ||||
| cpe:2.3:o:siemens:dk_standard_ethernet_controller_firmware:4.1.1:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:dk_standard_ethernet_controller:-:*:*:*:*:*:*:* | ||||
| Configuration46 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:*:*:*:*:*:*:*:* | 4.4.0 | ||||
| cpe:2.3:o:siemens:ek-ertec_200p_pn_io_firmware:4.4.0:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:ek-ertec_200p_pn_io:-:*:*:*:*:*:*:* | ||||
| Configuration47 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:*:*:*:*:*:*:*:* | 4.2.1 | ||||
| cpe:2.3:o:siemens:ek-ertec_200_pn_io_firmware:4.2.1:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:ek-ertec_200_pn_io:-:*:*:*:*:*:*:* | ||||
| Configuration48 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_s7-200_smart_firmware:*:*:*:*:*:*:*:* | 2.3 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_s7-200_smart:-:*:*:*:*:*:*:* | ||||
| Configuration49 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_s7-300_firmware:-:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_s7-300:-:*:*:*:*:*:*:* | ||||
| Configuration50 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_s7-400_firmware:*:*:*:*:*:*:*:* | 6.0.6 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_s7-400:-:*:*:*:*:*:*:* | ||||
| Configuration51 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_s7-1200_firmware:*:*:*:*:*:*:*:* | 4.2.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_s7-1200:-:*:*:*:*:*:*:* | ||||
| Configuration52 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_s7-1500_firmware:*:*:*:*:*:*:*:* | 2.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_s7-1500:-:*:*:*:*:*:*:* | ||||
| Configuration53 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_s7-1500_software_controller_firmware:*:*:*:*:*:*:*:* | 2.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_s7-1500_software_controller:-:*:*:*:*:*:*:* | ||||
| Configuration54 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:* | 2010 | ||||
| cpe:2.3:o:siemens:simatic_winac_rtx_firmware:2010:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:* | ||||
| Configuration55 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sirius_act_3su1_firmware:*:*:*:*:*:*:*:* | 1.1.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sirius_act_3su1:-:*:*:*:*:*:*:* | ||||
| Configuration56 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sirius_soft_starter_3rw44_pn_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sirius_soft_starter_3rw44_pn:-:*:*:*:*:*:*:* | ||||
| Configuration57 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sirius_motor_starter_m200d_profinet_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sirius_motor_starter_m200d_profinet:-:*:*:*:*:*:*:* | ||||
| Configuration58 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simocode_pro_v_profinet_firmware:*:*:*:*:*:*:*:* | 2.0.0 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simocode_pro_v_profinet:-:*:*:*:*:*:*:* | ||||
| Configuration59 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics_dcm_firmware:*:*:*:*:*:*:*:* | 1.4 | ||||
| cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:sp1:*:*:*:*:*:* | |||||
| cpe:2.3:o:siemens:sinamics_dcm_firmware:1.4:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinamics_dcm:-:*:*:*:*:*:*:* | ||||
| Configuration60 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics_dcp_firmware:*:*:*:*:*:*:*:* | 1.2 | ||||
| cpe:2.3:o:siemens:sinamics_dcp_firmware:1.2:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinamics_dcp:-:*:*:*:*:*:*:* | ||||
| Configuration61 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics_g110m_firmware:*:*:*:*:*:*:*:* | 4.7 | ||||
| cpe:2.3:o:siemens:sinamics_g110m_firmware:4.7:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinamics_g110m:-:*:*:*:*:*:*:* | ||||
| Configuration62 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics_g120\(c\/p\/d\)_w._pn_firmware:*:*:*:*:*:*:*:* | 4.7 | ||||
| cpe:2.3:o:siemens:sinamics_g120\(c\/p\/d\)_w._pn_firmware:4.7:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinamics_g120\(c\/p\/d\)_w._pn:-:*:*:*:*:*:*:* | ||||
| Configuration63 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics_g130_firmware:*:*:*:*:*:*:*:* | 4.7 | ||||
| cpe:2.3:o:siemens:sinamics_g130_firmware:4.7:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinamics_g130:-:*:*:*:*:*:*:* | ||||
| Configuration64 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics_g150_firmware:*:*:*:*:*:*:*:* | 4.7 | ||||
| cpe:2.3:o:siemens:sinamics_g150_firmware:4.7:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinamics_g150:-:*:*:*:*:*:*:* | ||||
| Configuration65 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics__s110_pn_firmware:*:*:*:*:*:*:*:* | 4.4 | ||||
| cpe:2.3:o:siemens:sinamics__s110_pn_firmware:4.4:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:_s110_pn:-:*:*:*:*:*:*:* | ||||
| Configuration66 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics_s120_firmware:*:*:*:*:*:*:*:* | 4.7 | ||||
| cpe:2.3:o:siemens:sinamics_s120_firmware:4.7:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinamics_s120:-:*:*:*:*:*:*:* | ||||
| Configuration67 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics_s150_firmware:*:*:*:*:*:*:*:* | 4.7 | ||||
| cpe:2.3:o:siemens:sinamics_s150_firmware:4.7:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinamics_s150:-:*:*:*:*:*:*:* | ||||
| Configuration68 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics_v90_pn_firmware:*:*:*:*:*:*:*:* | 1.01 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinamics_v90_pn:-:*:*:*:*:*:*:* | ||||
| Configuration69 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simotion_firmware:*:*:*:*:*:*:*:* | 4.5 | ||||
| cpe:2.3:o:siemens:simotion_firmware:4.5:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simotion:-:*:*:*:*:*:*:* | ||||
| Configuration70 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinumerik_828d_firmware:*:*:*:*:*:*:*:* | 4.5 | ||||
| cpe:2.3:o:siemens:sinumerik_828d_firmware:4.5:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinumerik_828d:-:*:*:*:*:*:*:* | ||||
| Configuration71 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:*:*:*:*:*:*:*:* | 4.5 | ||||
| cpe:2.3:o:siemens:sinumerik_840d_sl_firmware:4.5:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinumerik_840d_sl:-:*:*:*:*:*:*:* | ||||
| Configuration72 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_comfort_panels:*:*:*:*:*:*:*:* | 15.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:* | ||||
| Configuration73 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_multi_panels:*:*:*:*:*:*:*:* | 15.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_multi_panels:-:*:*:*:*:*:*:* | ||||
| Configuration74 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_hmi_mobile_panels:*:*:*:*:*:*:*:* | 15.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_hmi_mobile_panels:-:*:*:*:*:*:*:* | ||||
| Configuration75 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_1243-1_irc_firmware:*:*:*:*:*:*:*:* | 2.1.82 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_1243-1_irc:-:*:*:*:*:*:*:* | ||||
| Configuration76 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_1243-1_iec_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_1243-1_iec:-:*:*:*:*:*:*:* | ||||
| Configuration77 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_1243-1_dnp3_firmware:*:*:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_1243-1_dnp3:-:*:*:*:*:*:*:* | ||||
| Configuration78 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_dk-1604_pn_io_firmware:*:*:*:*:*:*:*:* | 2.7 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_dk-1604_pn_io:-:*:*:*:*:*:*:* | ||||
| Configuration79 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:* | 1.1.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:* | ||||
| Configuration80 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:* | 1.1.8 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:* | ||||
| Configuration81 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics_gh150_firmware:*:*:*:*:*:*:*:* | 4.7 | ||||
| cpe:2.3:o:siemens:sinamics_gh150_firmware:4.7:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinamics_gh150:-:*:*:*:*:*:*:* | ||||
| Configuration82 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics_gl150_firmware:*:*:*:*:*:*:*:* | 4.8 | ||||
| cpe:2.3:o:siemens:sinamics_gl150_firmware:4.8:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinamics_gl150:-:*:*:*:*:*:*:* | ||||
| Configuration83 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics_gm150_firmware:*:*:*:*:*:*:*:* | 4.7 | ||||
| cpe:2.3:o:siemens:sinamics_gm150_firmware:4.7:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinamics_gm150:-:*:*:*:*:*:*:* | ||||
| Configuration84 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics_sl150_firmware:*:*:*:*:*:*:*:* | 4.8 | ||||
| cpe:2.3:o:siemens:sinamics_sl150_firmware:4.8:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinamics_sl150:-:*:*:*:*:*:*:* | ||||
| Configuration85 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:sinamics_sm120_firmware:*:*:*:*:*:*:*:* | 4.8 | ||||
| cpe:2.3:o:siemens:sinamics_sm120_firmware:4.8:-:*:*:*:*:*:* | |||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:sinamics_sm120:-:*:*:*:*:*:*:* | ||||
| Configuration86 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:extension_unit_12_profinet_firmware:*:*:*:*:*:*:*:* | 01.01.01 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:extension_unit_12_profinet:-:*:*:*:*:*:*:* | ||||
| Configuration87 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:extension_unit_15_profinet_firmware:*:*:*:*:*:*:*:* | 01.01.01 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:extension_unit_15_profinet:-:*:*:*:*:*:*:* | ||||
| Configuration88 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:extension_unit_19_profinet_firmware:*:*:*:*:*:*:*:* | 01.01.01 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:extension_unit_19_profinet:-:*:*:*:*:*:*:* | ||||
| Configuration89 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:extension_unit_22_profinet_firmware:*:*:*:*:*:*:*:* | 01.01.01 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:extension_unit_22_profinet:-:*:*:*:*:*:*:* | ||||
| Configuration90 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_1242-7_gprs_firmware:*:*:*:*:*:*:*:* | 2.1.82 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_1242-7_gprs:-:*:*:*:*:*:*:* | ||||
| Configuration91 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_1243-7_lte\/us_firmware:*:*:*:*:*:*:*:* | 2.1.82 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_1243-7_lte\/us:-:*:*:*:*:*:*:* | ||||
| Configuration92 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_1243-8_firmware:*:*:*:*:*:*:*:* | 2.1.82 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_1243-8:-:*:*:*:*:*:*:* | ||||
| Configuration93 | or higher | or less | more than | less than | |
| cpe:2.3:o:siemens:simatic_cp_1626_firmware:*:*:*:*:*:*:*:* | 1.1 | ||||
| execution environment | |||||
| 1 | cpe:2.3:h:siemens:simatic_cp_1626:-:*:*:*:*:*:*:* | ||||
| Title | 複数の Siemens 製品におけるサービス運用妨害 (DoS) の脆弱性 |
|---|---|
| Summary | 複数の Siemens 製品には、サービス運用妨害 (DoS) 状態にされる脆弱性が存在します。 |
| Possible impacts | 巧妙に細工された PROFINET DCP ブロードキャスト (Layer 2 - Ethernet) パケットを介して、サービス運用妨害 (DoS) 状態にされる可能性があります。 |
| Solution | ベンダより正式な対策が公開されています。ベンダ情報を参照して適切な対策を実施してください。 |
| Publication Date | May 8, 2017, midnight |
| Registration Date | June 16, 2017, 6:11 p.m. |
| Last Update | May 10, 2018, 5:29 p.m. |
| シーメンス |
| DK Standard Ethernet Controller ファームウェア |
| EK-ERTEC 200 PN IO ファームウェア |
| EK-ERTEC 200P PN IO ファームウェア |
| IE/AS-i Link PN IO ファームウェア |
| IE/PB-Link ファームウェア |
| PN/PN Coupler ファームウェア |
| SCALANCE M-800 ファームウェア |
| SCALANCE S615 ファームウェア |
| SCALANCE W700 ファームウェア |
| SCALANCE X200 IRT ファームウェア |
| SCALANCE X200 ファームウェア |
| SCALANCE X300 ファームウェア |
| SCALANCE X408 ファームウェア |
| SCALANCE X414 ファームウェア |
| SCALANCE XM400 ファームウェア |
| SCALANCE XR500 ファームウェア |
| SIMATIC CM 1542-1 ファームウェア |
| SIMATIC CP 1243-1 ファームウェア |
| SIMATIC CP 1542SP-1 IRC ファームウェア |
| SIMATIC CP 1542SP-1 ファームウェア |
| SIMATIC CP 1543-1 ファームウェア |
| SIMATIC CP 1543SP-1 ファームウェア |
| SIMATIC CP 1604 ファームウェア |
| SIMATIC CP 1616 ファームウェア |
| SIMATIC CP 343-1 Adv ファームウェア |
| SIMATIC CP 343-1 Lean ファームウェア |
| SIMATIC CP 343-1 Std ファームウェア |
| SIMATIC CP 443-1 Adv ファームウェア |
| SIMATIC CP 443-1 OPC-UA ファームウェア |
| SIMATIC CP 443-1 Std ファームウェア |
| SIMATIC DK-16xx PN IO ファームウェア |
| SIMATIC ET 200AL ファームウェア |
| SIMATIC ET 200ecoPN ファームウェア |
| SIMATIC ET 200M ファームウェア |
| SIMATIC ET 200MP ファームウェア |
| SIMATIC ET 200pro ファームウェア |
| SIMATIC ET 200S ファームウェア |
| SIMATIC ET 200SP ファームウェア |
| SIMATIC HMI Comfort Panels ファームウェア |
| SIMATIC HMI Mobile Panels ファームウェア |
| SIMATIC HMI Multi Panels ファームウェア |
| SIMATIC RF650R ファームウェア |
| SIMATIC RF680R ファームウェア |
| SIMATIC RF685R ファームウェア |
| SIMATIC S7-1200 ファームウェア |
| SIMATIC S7-1500 Software Controller ファームウェア |
| SIMATIC S7-1500 ファームウェア |
| SIMATIC S7-200 SMART ファームウェア |
| SIMATIC S7-300 ファームウェア |
| SIMATIC S7-400 ファームウェア |
| SIMATIC Teleservice Adapter IE Advanced ファームウェア |
| SIMATIC Teleservice Adapter IE Basic ファームウェア |
| SIMATIC Teleservice Adapter Standard Modem ファームウェア |
| SIMATIC WinAC RTX 2010 ファームウェア |
| SIMOCODE pro V PROFINET ファームウェア |
| SIMOTION ファームウェア |
| SINAMICS DCM ファームウェア |
| SINAMICS DCP ファームウェア |
| SINAMICS G110M ファームウェア |
| SINAMICS G120(C/P/D) w. PN ファームウェア |
| SINAMICS G130 ファームウェア |
| SINAMICS G150 ファームウェア |
| SINAMICS S110 w. PN ファームウェア |
| SINAMICS S120 ファームウェア |
| SINAMICS S150 ファームウェア |
| SINAMICS V90 w. PN ファームウェア |
| SINUMERIK 828D ファームウェア |
| SINUMERIK 840D sl ファームウェア |
| SIRIUS ACT 3SU1 interface module PROFINET ファームウェア |
| SIRIUS Motor starter M200D PROFINET ファームウェア |
| SIRIUS Soft starter 3RW44 PN ファームウェア |
| SITOP PSU8600 ファームウェア |
| SITOP UPS1600 PROFINET ファームウェア |
| Softnet PROFINET IO for PC-based Windows systems ファームウェア |
| No | Changed Details | Date of change |
|---|---|---|
| 0 | [2017年06月16日] 掲載 [2017年09月11日] 参考情報:ICS-CERT ADVISORY (ICSA-17-129-02) を追加 [2018年01月24日] 影響を受けるシステム:参考情報の追加に伴い内容を更新 参考情報:ICS-CERT ADVISORY (ICSA-18-023-02) を追加 |
Feb. 17, 2018, 10:37 a.m. |
| 1 | [2018年05月10日] 参考情報:ICS-CERT ADVISORY (ICSA-18-128-01) を追加 |
May 10, 2018, 5:22 p.m. |