CVE-2014-5431
| Summary |
Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 contains a hard-coded password, which provides access to basic biomedical information, limited device settings, and network configuration of the WBM, if connected. The hard-coded password may allow an attacker with physical access to the device to access management functions to make unauthorized configuration changes to biomedical settings such as turn on and off wireless connections and the phase-complete audible alarm that indicates the end of an infusion phase. Baxter has released a new version of the SIGMA Spectrum Infusion System, version 8, which incorporates hardware and software changes.
|
| Publication Date |
March 27, 2019, 1:29 a.m. |
| Registration Date |
Jan. 26, 2021, 3:14 p.m. |
| Last Update |
Nov. 21, 2024, 11:12 a.m. |
|
CVSS3.0 : MEDIUM
|
| スコア |
6.8
|
| Vector |
CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| 攻撃元区分(AV) |
物理 |
| 攻撃条件の複雑さ(AC) |
低 |
| 攻撃に必要な特権レベル(PR) |
不要 |
| 利用者の関与(UI) |
不要 |
| 影響の想定範囲(S) |
変更なし |
| 機密性への影響(C) |
高 |
| 完全性への影響(I) |
高 |
| 可用性への影響(A) |
高 |
|
CVSS2.0 : MEDIUM
|
| Score |
4.6
|
| Vector |
AV:L/AC:L/Au:N/C:P/I:P/A:P |
| 攻撃元区分(AV) |
ローカル |
| 攻撃条件の複雑さ(AC) |
低 |
| 攻撃前の認証要否(Au) |
不要 |
| 機密性への影響(C) |
低 |
| 完全性への影響(I) |
低 |
| 可用性への影響(A) |
低 |
| Get all privileges. |
いいえ
|
| Get user privileges |
いいえ
|
| Get other privileges |
いいえ
|
| User operation required |
いいえ
|
Affected software configurations
| Configuration1 |
or higher |
or less |
more than |
less than |
| cpe:2.3:o:baxter:sigma_spectrum_infusion_system_firmware:6.05:*:*:*:*:*:*:* |
|
|
|
|
| execution environment |
| 1 |
cpe:2.3:h:baxter:sigma_spectrum_infusion_system:-:*:*:*:*:*:*:* |
| 2 |
cpe:2.3:h:baxter:wireless_battery_module:16:*:*:*:*:*:*:* |
Related information, measures and tools
Common Vulnerabilities List
JVN Vulnerability Information
Baxter SIGMA Spectrum Infusion System におけるハードコードされた認証情報の使用に関する脆弱性
| Title |
Baxter SIGMA Spectrum Infusion System におけるハードコードされた認証情報の使用に関する脆弱性
|
| Summary |
Baxter SIGMA Spectrum Infusion System には、ハードコードされた認証情報の使用に関する脆弱性が存在します。
|
| Possible impacts |
情報を取得される、情報を改ざんされる、およびサービス運用妨害 (DoS) 状態にされる可能性があります。 |
| Solution |
ベンダ情報および参考情報を参照して適切な対策を実施してください。 |
| Publication Date |
Aug. 22, 2014, midnight |
| Registration Date |
May 9, 2019, 12:12 p.m. |
| Last Update |
May 9, 2019, 12:12 p.m. |
Affected System
| Baxter |
|
SIGMA Spectrum Infusion System ファームウェア 6.05 (model 35700BAX)
|
CVE (情報セキュリティ 共通脆弱性識別子)
CWE (共通脆弱性タイプ一覧)
ベンダー情報
その他
Change Log
| No |
Changed Details |
Date of change |
| 1 |
[2019年05月09日] 掲載 |
May 9, 2019, 12:12 p.m. |