CVE-2008-5423
| Summary |
Sun Sun Ray Server Software 3.x and 4.0 and Sun Ray Windows Connector 1.1 and 2.0 expose the LDAP password during a configuration step, which allows local users to discover the Sun Ray administration password, and obtain admin access to the Data Store and Administration GUI, via unspecified vectors related to the utconfig component of the Server Software and the uttscadm component of the Windows Connector.
|
| Publication Date |
Dec. 12, 2008, 12:30 a.m. |
| Registration Date |
Jan. 29, 2021, 1:46 p.m. |
| Last Update |
Oct. 31, 2018, 1:25 a.m. |
|
CVSS2.0 : MEDIUM
|
| Score |
4.3
|
| Vector |
AV:L/AC:L/Au:S/C:P/I:P/A:P |
| 攻撃元区分(AV) |
ローカル |
| 攻撃条件の複雑さ(AC) |
低 |
| 攻撃前の認証要否(Au) |
単一 |
| 機密性への影響(C) |
低 |
| 完全性への影響(I) |
低 |
| 可用性への影響(A) |
低 |
| Get all privileges. |
いいえ
|
| Get user privileges |
いいえ
|
| Get other privileges |
いいえ
|
| User operation required |
いいえ
|
Affected software configurations
| Configuration1 |
or higher |
or less |
more than |
less than |
| cpe:2.3:a:sun:ray_server_software:3.0:*:sparc:*:*:*:*:* |
|
|
|
|
| cpe:2.3:a:sun:ray_server_software:3.1:*:sparc:*:*:*:*:* |
|
|
|
|
| cpe:2.3:a:sun:ray_server_software:4.0:*:sparc:*:*:*:*:* |
|
|
|
|
| execution environment |
| 1 |
cpe:2.3:o:sun:solaris:8:*:sparc:*:*:*:*:* |
| 2 |
cpe:2.3:o:sun:solaris:9:*:sparc:*:*:*:*:* |
| 3 |
cpe:2.3:o:sun:solaris:10:*:sparc:*:*:*:*:* |
| Configuration2 |
or higher |
or less |
more than |
less than |
| cpe:2.3:a:sun:ray_server_software:3.1:*:x86:*:*:*:*:* |
|
|
|
|
| cpe:2.3:a:sun:ray_server_software:4.0:*:x86:*:*:*:*:* |
|
|
|
|
| execution environment |
| 1 |
cpe:2.3:o:sun:solaris:10:*:x86:*:*:*:*:* |
| Configuration3 |
or higher |
or less |
more than |
less than |
| cpe:2.3:a:sun:ray_windows_connector:1.1:*:sparc:*:*:*:*:* |
|
|
|
|
| cpe:2.3:a:sun:ray_windows_connector:2.0:*:sparc:*:*:*:*:* |
|
|
|
|
| cpe:2.3:a:sun:ray_server_software:3.1:*:sparc:*:*:*:*:* |
|
|
|
|
| cpe:2.3:a:sun:ray_server_software:4.0:*:sparc:*:*:*:*:* |
|
|
|
|
| Configuration4 |
or higher |
or less |
more than |
less than |
| cpe:2.3:a:sun:ray_windows_connector:1.1:*:x86:*:*:*:*:* |
|
|
|
|
| cpe:2.3:a:sun:ray_windows_connector:2.0:*:x86:*:*:*:*:* |
|
|
|
|
| cpe:2.3:a:sun:ray_server_software:3.1:*:x86:*:*:*:*:* |
|
|
|
|
| cpe:2.3:a:sun:ray_server_software:4.0:*:x86:*:*:*:*:* |
|
|
|
|
| Configuration5 |
or higher |
or less |
more than |
less than |
| cpe:2.3:a:sun:ray_windows_connector:1.1:*:linux:*:*:*:*:* |
|
|
|
|
| cpe:2.3:a:sun:ray_windows_connector:2.0:*:linux:*:*:*:*:* |
|
|
|
|
| cpe:2.3:a:sun:ray_server_software:3.1.1:*:linux:*:*:*:*:* |
|
|
|
|
| cpe:2.3:a:sun:ray_server_software:4.0:*:linux:*:*:*:*:* |
|
|
|
|
| Configuration6 |
or higher |
or less |
more than |
less than |
| cpe:2.3:a:sun:ray_server_software:3.1.1:*:linux:*:*:*:*:* |
|
|
|
|
| cpe:2.3:a:sun:ray_server_software:4.0:*:linux:*:*:*:*:* |
|
|
|
|
| execution environment |
| 1 |
cpe:2.3:o:novell:suse_linux_enterprise_server:9:*:*:*:*:*:*:* |
| 2 |
cpe:2.3:o:redhat:enterprise_linux:4:*:advanced_server:*:*:*:*:* |
| Configuration7 |
or higher |
or less |
more than |
less than |
| cpe:2.3:a:sun:ray_server_software:3.0:*:linux:*:*:*:*:* |
|
|
|
|
| cpe:2.3:a:sun:ray_server_software:3.1:*:linux:*:*:*:*:* |
|
|
|
|
| execution environment |
| 1 |
cpe:2.3:a:sun:java_desktop_system:2.0:*:*:*:*:*:*:* |
| 2 |
cpe:2.3:o:novell:suse_linux_enterprise_server:8:*:*:*:*:*:*:* |
| 3 |
cpe:2.3:o:redhat:enterprise_linux:3:*:advanced_server:*:*:*:*:* |
Related information, measures and tools
Common Vulnerabilities List
JVN Vulnerability Information
Sun Sun Ray Server Software などにおける Sun Ray 管理者パスワードを特定される脆弱性
| Title |
Sun Sun Ray Server Software などにおける Sun Ray 管理者パスワードを特定される脆弱性
|
| Summary |
Sun Sun Ray Server Software および Sun Ray Windows Connector は、設定ステップ中に LDAP パスワードを保護しない、および Server Software の utconfig コンポーネントおよび Windows Connector の uttscadm コンポーネントに関する処理に不備があるため、Sun Ray 管理者パスワードを特定される、および Data Store および Administration GUI への管理アクセス権限を取得される脆弱性が存在します。
|
| Possible impacts |
ローカルユーザにより、Sun Ray 管理者パスワードを特定される、および Data Store および Administration GUI への管理アクセス権限を取得される可能性があります。 |
| Solution |
ベンダより正式な対策が公開されています。ベンダ情報を参照して適切な対策を実施してください。 |
| Publication Date |
Dec. 4, 2008, midnight |
| Registration Date |
Dec. 20, 2012, 6:52 p.m. |
| Last Update |
Dec. 20, 2012, 6:52 p.m. |
Affected System
| サン・マイクロシステムズ |
|
ray server software 3.x および 4.0
|
|
ray windows connector 1.1 および 2.0
|
CVE (情報セキュリティ 共通脆弱性識別子)
CWE (共通脆弱性タイプ一覧)
ベンダー情報
Change Log
| No |
Changed Details |
Date of change |
| 0 |
[2012年12月20日] 掲載 |
Feb. 17, 2018, 10:37 a.m. |